This Handheld Telemetry Display with Multiple Inputs module provides an 8 digit LCD reading from up to 12 of the T24 Acquisition modules (strain gauge, voltage, current, temperature, pulse and potentiometer ). The T24-HA can be operated in two modes:
The acquisition modules can be ‘powered on’ and ‘powered off’ automatically by the T24-HA handheld. Status indicators inform the user if the remote acquisition module has input integrity problems, low battery, low signal, over range or other error. The display can be toggled between gross and a tared value and can optionally be scaled to change measurement units.
In addition, a function key can be configured to retransmit the displayed value to other T24 modules such as a printer.
The licence free 2.4GHz direct sequence spread spectrum (DSSS) radio telemetry technology offers high integrity, error free communications which can co-exist with other wireless technologies such as Wi-Fi, Bluetooth® and Zigbee®. FCC, ETSI and IC approvals.
This Handheld Telemetry Display with Multiple Inputs module uses a pair of standard alkaline AA batteries and is configured using free T24 Toolkit software which runs on a PC connected to a T24 base station.
The T24-HA handheld display is typically seen in applications requiring wireless loadcell measurement or wireless strain gauge display.
Min | Typical | Max | Units | |
---|---|---|---|---|
Licence | 1 | Licence Exempt | 1 | 1 |
Modulation method | MS (QPSK) | |||
Radio Type | Transceiver (2 way) | |||
Data Rate | 250 | K bits/sec | ||
Radio Frequency | 2.4000 | 2.4835 | GHz | |
Power | 1 | mw | ||
Range | 800 (2600) | Metres (feet) * | ||
Channels (DSSS) | 16 |
*Maximum range achieved in open field site at a height of 3 metres (9.8 feet) above ground.
Electrical | Min | Typical | Max | Units |
---|---|---|---|---|
Power Supply Voltage | 2.4 | 3.0 | 3.6 | V dc |
Power Consumption | ||||
Active | 35 | 40 | mA | |
Low Power Mode | 120 | 160 | uA | |
Estimated Battery Life using 2Ah Batteries: | ||||
Standby Mode (Powered off) | 1.5 | Years | ||
Continuous Operation | 40 | Hours | ||
Environmental | ||||
IP Rating | IP67 / | |||
Operating Temperature Range | -10 | +50 | C | |
Storage Temperature | -40 | +85 | C | |
Humidity | 0 | 95 | %RH |
Model | Code |
---|---|
Digital Display for up to 12 Inputs | T24-HA |
Black leather case with clear viewing window with shoulder strap | TR100-CA |
File | Date | Size | |
---|---|---|---|
Handheld telemetry display with multiple inputs T24-HA datasheet (English) | 28-08-2015 | 590KB | |
Handheld telemetry display with multiple inputs T24-HA operating manual (English) | 28-08-2015 | 1.1MB | |
T24 telemetry systems user's manual (English) | 02-08-2021 | 12.3MB | |
T24 Toolkit v02.15.04 software - Configuration, calibration and testing of T24 range telemetry products | 15-06-2023 | 7.0MB | |
T24 Windows Drivers - Development files (DLLs, COM drivers - ActiveX, .NET, LabView) | 16-10-2018 | 6.2MB |