The ICA family offers high stability and fast response strain gauge or load cell amplifier, converting a strain gauge input into a volt or mA output.
It’s sub-miniature design enables it to be fitted into the majority of transducers for a wide range of signal conditioning for strain gauges, load cells, pressure and torque transducers.
Available in 6 versions, 5 with high performance and ICA5S with industrial stability.
The ICAH range offer very low drift over wide operating temperatures. Optional (ILE) in line enclosure to convert a standard load cell to a conditioned load cell output.
ICA1,2,3,6H Voltage Output Amplifiers | ||||
|---|---|---|---|---|
ICA1H 0.1-10.1 V | ||||
| Parameter | Min | Typical | Max | Units/Notes |
| Electrical & Environmental | ||||
| Supply Voltage Range | 13 | 24 | 30 | Volts |
| Operating Current | 22 | mA Note 1 | ||
| Operating Temp Range | -40 | 85 | ºC | |
| Storage Temp Range | -40 | 85 | ºC | |
| Reverse Polarity Protection | -30 | Volts | ||
| Measurements | ||||
| Bridge Excitation | 4.9 | 5 | 5.1 | Volts |
| Bridge Impedance | 350 | 1000 | 5000 | Ohms |
| Bridge Sensitivity | 0.5 | 2.5 | 150 | mV/V Note 2 |
| Output Voltage Range | 0.1 | +10.1 | Volts | |
| Output Load | 5000 | Ohms | ||
| Band Width | DC | 1000 | Hz | |
| Zero Adjustment | ±2 | %FR | ||
| Span Adjustment | ±8 | %FR | ||
| Linearity | 0.02 | %FR | ||
| Zero Temp Stability H | 0.0004 | 0.0015 | ±%FR/ºC | |
| Span Temp Stability H | 0.002 | 0.0051 | ±%FR/ºC | |
ICA2H 0.1-5.1 V | ||||
|---|---|---|---|---|
| Electrical & Environmental | ||||
| Supply Voltage Range | 8.5 | 12 | 28 | Volts |
| Operating Current | 22 | mA Note 1 | ||
| Operating Temp Range | -40 | 85 | ºC | |
| Storage Temp Range | -40 | 85 | ºC | |
| Reverse Polarity Protection | -30 | Volts | ||
| Measurements | ||||
| Bridge Excitation | 4.9 | 5 | 5.1 | Volts |
| Bridge Impedance | 350 | 1000 | 5000 | Ohms |
| Bridge Sensitivity | 0.5 | 2.5 | 150 | mV/V Note 2 |
| Output Voltage Range | 0.1 | +5.1 | Volts | |
| Output Load | 5000 | Ohms | ||
| Band Width | DC | 1000 | Hz | |
| Zero Adjustment | ±2 | %FR | ||
| Span Adjustment | ±8 | %FR | ||
| Linearity | 0.02 | %FR | ||
| Zero Temp Stability H | 0.0004 | 0.0015 | ±%FR/ºC | |
| Span Temp Stability H | 0.002 | 0.0051 | ±%FR/ºC | |
ICA3H ±10 V | ||||
|---|---|---|---|---|
| Electrical & Environmental | ||||
| Supply Voltage Range | ±13 | ±14 | ±15 | Volts |
| Operating Current | 22 | mA Note 1 | ||
| Operating Temp Range | -40 | 85 | ºC | |
| Storage Temp Range | -40 | 85 | ºC | |
| Reverse Polarity Protection | -30 | Volts | ||
| Measurements | ||||
| Bridge Excitation | 4.9 | 5 | 5.1 | Volts |
| Bridge Impedance | 350 | 1000 | 5000 | Ohms |
| Bridge Sensitivity | 0.5 | 2.5 | 150 | mV/V Note 2 |
| Output Voltage Range | -10 | +10 | Volts | |
| Output Load | 5000 | Ohms | ||
| Band Width | DC | 1000 | Hz | |
| Zero Adjustment | ±2 | %FR | ||
| Span Adjustment | ±8 | %FR | ||
| Linearity | 0.02 | %FR | ||
| Zero Temp Stability H | 0.0004 | 0.0015 | ±%FR/ºC | |
| Span Temp Stability H | 0.002 | 0.0051 | ±%FR/ºC | |
ICA6H ±10 V | ||||
|---|---|---|---|---|
| Electrical & Environmental | ||||
| Supply Voltage Range | 14 | 15 | 18 | Volts Note 3 |
| Operating Current | 30 | mA Note 1 | ||
| Operating Temp Range | -40 | 85 | ºC | |
| Storage Temp Range | -40 | 85 | ºC | |
| Reverse Polarity Protection | -30 | Volts | ||
| Measurements | ||||
| Bridge Excitation | 4.9 | 5 | 5.1 | Volts |
| Bridge Impedance | 350 | 1000 | 5000 | Ohms |
| Bridge Sensitivity | 0.5 | 2.5 | 150 | mV/V Note 2 |
| Output Voltage Range | -10 | +10 | Volts | |
| Output Load | 5000 | Ohms | ||
| Band Width | DC | 1000 | Hz | |
| Zero Adjustment | ±2 | %FR | ||
| Span Adjustment | ±8 | %FR | ||
| Linearity | 0.02 | %FR | ||
| Zero Temp Stability H | 0.0004 | 0.0015 | ±%FR/ºC | |
| Span Temp Stability H | 0.002 | 0.0051 | ±%FR/ºC | |
ICA4H, ICA5S Current Output Amplifiers | ||||
|---|---|---|---|---|
ICA4H 4-20 mA | ||||
| Electrical & Environmental | ||||
| Supply Voltage Range | 10 | 24 | 30 | Volts Note 4 |
| Operating Current | 26 | 42 | mA Note 1 | |
| Operating Temp Range | -40 | 85 | ºC | |
| Storage Temp Range | -40 | 85 | ºC | |
| Reverse Polarity Protection | -30 | Volts | ||
| Measurements | ||||
| Bridge Excitation | 4.9 | 5 | 5.1 | Volts |
| Bridge Impedance | 350 | 1000 | 5000 | Ohms |
| Bridge Sensitivity | 0.5 | 2.5 | 150 | mV/V Note 2 |
| Output Current Range | 4 | 20 | mA | |
| Output Load | 1000 | Ohms Note 7 | ||
| Band Width | DC | 1000 | Hz | |
| Zero Adjustment | ±2 | %FR | ||
| Span Adjustment | ±8 | %FR | ||
| Linearity | 0.02 | %FR | ||
| Zero Temp Stability S | 0.0009 | 0.0025 | ±%FR/ºC | |
| Zero Temp Stability H | 0.0004 | 0.0015 | ±%FR/ºC | |
| Span Temp Stability S | 0.0025 | 0.0064 | ±%FR/ºC | |
| Span Temp Stability H | 0.002 | 0.0051 | ±%FR/ºC | |
ICA5S 4-20 mA | ||||
|---|---|---|---|---|
| Electrical & Environmental | ||||
| Supply voltage Range | 7.5 | 24 | 30 | Volts |
| Operating Current | 4 | 20 | mA (2 wire) | |
| Operating Temp Range | -40 | 85 | ºC | |
| Storage Temp Range | -40 | 85 | ºC | |
| Reverse Polarity Protection | -30 | Volts | ||
| Measurements | ||||
| Bridge Excitation | 1.05 | 1.11 | 1.16 | Volts Note 5 |
| Bridge Impedance | 350 | 1000 | 5000 | Ohms Note 6 |
| Bridge Sensitivity | 0.5 | 2.5 | 55 | mV/V Note 2 |
| Output Current Range | 4 | 20 | mA | |
| Output Load | 800 | Ohms | ||
| Band Width | DC | 1000 | Hz | |
| Zero Adjustment | ±2 | %FR Note 5 | ||
| Span Adjustment | ±8 | %FR | ||
| Linearity | 0.02 | %FR | ||
| Zero Temp Stability S | 0.001 | 0.005 | ±%FR/ºC | |
| Span Temp Stability S | 0.007 | 0.014 | ±%FR/ºC | |
ICA5A 4-20mA | ||||
|---|---|---|---|---|
| Electrical & Environmental | ||||
| Supply Voltage Range | 9 | 24 | 30 | Volts |
| Operating Current | 4 | 20 | mA (2 wire) | |
| Operating Temp Range | -40 | 85 | ºC | |
| Storage Temp Range | -40 | 85 | ºC | |
| Reverse Polarity Protection | -30 | Volts | ||
| Measurements | ||||
| Bridge Excitation | 1.05 | 1.11 | 1.16 | Volts Note 5 |
| Bridge Impedance | 350 | 1000 | 5000 | Ohms Note 6 |
| Bridge Sensitivity | 0.5 | 2.5 | 55 | mV/V Note 2 |
| Output Current Range | 4 | 20 | mA | |
| Output Load | 700 | Ohms | ||
| Band Width | DC | 1000 | Hz | |
| Zero Adjustment | ±2 | %FR Note 5 | ||
| Span Adjustment | ±8 | %FR | ||
| Linearity | 0.02 | %FR | ||
| Zero Temp Stability S | 0.001 | 0.005 | ±%FR/ºC | |
| Span Temp Stability S | 0.007 | 0.014 | ±%FR/ºC | |
| Notes | Note 1 - With 350 Ohm load cell connected. | |||
| General Notes | The voltage between either of the power supply connections and the load cell shield should not exceed 50V. Any leakage will be greater than 10M Ohms. FR = Full Range | |||
| Environmental | ||||
| Storage Temperature | -40 to +85ºC | |||
| Operating Temperature | -40 to +85ºC | |||
| Relative Humidity | 95% maximum non condensing | |||
| CE Environmental Approvals | European EMC Directive 2004/108/EC, Low Voltage Directive 2006/95/EC | |||
| ICA H High Stablility | Code |
|---|---|
| 3 Wire 0.1 - 10.1 V | ICA1H |
| 3 Wire 0.1 - 5.1V | ICA2H |
| 4 Wire ±10 V | ICA3H |
| 3 Wire 4-20 mA | ICA4H |
| 3 Wire ±10 V 14-24 V | ICA6H |
| ICA S Industrial Stability | Code |
| 2 Wire 4-20 mA | ICA5S |
| Intrinsically safe (ATEX certified) | Code |
| 2 Wire 4-20 mA | ICA5ATEX |
| 2 Wire 4-20 mA conditioner + ILEATEX enclosure | ALA5 |
| Enclosure | Code |
| In-Line Housing for Load Cell Amplifiers & Digital Converters | ILE |
| In-Line Housing for Load Cell Amplifiers & Digital Converters (ATEX approved) | ILEATEX |
| File | Date | Size | |
|---|---|---|---|
| Strain gauge signal conditioner ICA H & S datasheet (English) | 02/09/2015 | 493KB | |
| Strain gauge signal conditioners ICA Series instruction manual (English) | 02/09/2015 | 1.0MB | |
| Strain gauge signal conditioner ICA1 and ICA2 H & S instruction manual (English) | 02/09/2015 | 710KB | |
| Strain gauge signal conditioner ICA3 and ICA6 H & S instruction manual (English) | 02/09/2015 | 596KB | |
| Strain gauge signal conditioner ICA4 H & S instruction manual (English) | 02/09/2015 | 825KB | |
| Strain gauge signal conditioner ICA5 H & S instruction manual (English) | 02/09/2015 | 621KB | |
| Intrinsically safe strain gauge signal conditioner ALA5 (ICA5ATEX + ILEATEX) datasheet (English) | 02/09/2015 | 579KB | |
| Intrinsically safe strain gauge signal conditioner ALA5 (ICA5ATEX + ILEATEX) instruction manual (English) | 02/09/2015 | 2.0MB | |
| ILE Enclosure for ICA and DCell signal conditioners (English) | 01/09/2015 | 568KB | |
| Assembly instructions for ILE enclosure (English) | 01/09/2015 | 395KB | |
| ICA4, 5 and 6 3D drawing (.STEP format) | 02/09/2015 | 3.6MB |